The goal is not to buy the largest battery; it is to preserve communication, light and medically essential functions. List the real connectors, power needs and running time of each device. Do not promise a number of phone charges from an advertised capacity alone.
A testable basic kit
- Accessible LED torches for people who may need to move, with spare batteries or charged cells, kept in an agreed place.
- A phone, working cable, wall adapter and power bank. About 20,000 mAh is an illustrative family option, not a standard: at a nominal 3.7 V it is about 74 Wh before losses. Test your own phones and write down the actual result.
- Plan a second independent charging route and an official information channel that works without mobile data when communication is critical. Keep numbers on paper.
- For powered medical equipment, agree backup capacity with the clinician and supplier. A phone power bank may have the wrong voltage, connector or runtime.
Avoid new hazards
MChS warns not to leave batteries charging unattended or use damaged cables or overheated devices. Never charge them under a pillow or on a bed. Never operate a portable fuel-burning generator in an apartment, garage or other enclosed space because carbon monoxide can kill. Do not use outdoor-only stoves or heaters indoors, or heat a room with a gas hob. Prefer LED lighting to candles; do not improvise a connection to household wiring.
Check charge, cables and torches monthly. Each season, run a short “no power and no mobile data” exercise with the household.
Make a tested continuity sheet
List every essential dependency for your actual home: phone, light, water pump or lift, heating controls, communications equipment and any individual medical device. For each write what fails without power; the device's measured or rated load; hours needed; approved backup; tested runtime; next safe option. Prioritise a torch and a working way to receive official information before buying a larger system. A battery's advertised capacity is not the same as usable output after losses.
Set an exit or help threshold
Ask what happens when the reserve reaches its measured limit. Who checks an older neighbour? Where can a dependent person obtain power or care if a lift, pump or treatment device stops? For medical equipment, agree the threshold with the clinician and equipment supplier; do not infer it from a general website or connect an unapproved battery.
Pass check: the cable fits, the intended device runs in a normal-condition test, the result is recorded, and another person knows the fallback and the local electricity provider's update channel. Never operate a portable fuel-burning generator in a home, garage, tent or other enclosed space; do not use a charcoal grill or outdoor-only stove or heater indoors, and do not improvise wiring. Link this sheet to general power planning, winter outage and official alerts.
Checked 7 October 2026: MChS charging safety; MChS generator safety; MChS outage tips. The 20,000 mAh example is not an MChS requirement.